Following on from the first Stackup Planning columns, this month’s Part 3 will look at higher layer-count stackups. The four- and six-layer configurations are not the best choice for high-speed design. In particular, each signal layer should be adjacent to, and closely coupled to, an uninterrupted reference plane, which creates a clear return path and eliminates broadside crosstalk. As the layer count increases, these rules become easier to implement but decisions regarding return current paths become more challenging.

Given the luxury of more layers:

  • Electromagnetic compliancy (EMC) can be improved or more routing layers can be added.
  • Power and ground planes can be closely coupled to add planar capacitance, which is essential for GHz plus design.
  • The power distribution networks (PDNs) can be improved by substituting embedded capacitance material (ECM) for the planes.
  • Multiple power planes/pours can be defined to accommodate the high number of supplies required by today’s processors and FPGAs.
  • Multiple ground planes can be inserted to reduce the plane impedance and loop area.

Although power planes can be used as reference planes, ground is more effective because local stitching vias can be used for the return current transitions, rather than stitching decoupling capacitors which add inductance. This keeps the loop area small and reduces radiation. As the stackup layer count increases, so does the number of possible combinations of the structure. But, if one sticks to the basic rules, then the best performing configurations are obvious.

Figure 1 illustrates the spreading of return current density across the plane above and below the signal path. At high frequencies, the return current takes the path of least inductance. As the frequency approaches a couple of hundred MHz, the skin effect forces the return current to the surface (closest to the signal trace).

I previously mentioned that it is important to have a clearly defined current return path. But it is also important to know exactly where the return current will flow. This is particularly critical with asymmetric stripline configurations where one signal layer is sandwiched between two planes as in Figure 2. Now obviously, if the distance to the closest plane (h1) is the same distance as the far plane (h2) then the return current distribution will be equal on each plane (given the same inductance for each path). However, in order to force the current onto the ground (GND) plane of an unbalanced stripline configuration, h2 needs to be at least twice h1, and three times is better.

To read this entire column, which appeared in the August 2014 issue of The PCB Design Magazine, click here.

Share

Print


Suggested Items

Real Time with… AltiumLive 2020: Lawrence Romine on Successful U.S. Event

10/15/2020 | I-Connect007 Editorial Team
Andy Shaughnessy and Lawrence Romine, vice president of corporate marketing for Altium, discuss some of the lessons learned from last week's virtual U.S. AltiumLive, as well as what attendees can expect from the European show, which takes place October 20–22, 2020.

Combatting Thermal Challenges With TRM Software

10/07/2020 | I-Connect007 Editorial Team
Johannes Adam is the creator of a simulation tool called Thermal Risk Management (TRM) used to help PCB designers and design engineers predict hot spots on the board before during layout. He and Douglas Brooks, founder of UltraCAD Design, have used the tool to produce several technical articles and a book on the subject. In this interview, they tackle the biggest misconceptions they see from designers and engineers who deal with thermal management issues.

This Month in Design007 Magazine: Thermal Fundamentals With Mike Jouppi

09/09/2020 | I-Connect007 Editorial Team
The I-Connect007 team recently interviewed Mike Jouppi, one of the champions of thermal management in PCBs. Mike spent decades working on updating the old IPC current-carrying data, which dated back to the 1950s, and he is the primary architect behind IPC-2152— the standard for determining current-carrying capacity in printed board design. As Mike explained in this wide-ranging interview, even if you’re using the latest thermal design software, you still need to have a firm understanding of the fundamentals.



Copyright © 2020 I-Connect007. All rights reserved.